Skip to content
Home / Guides / How to read a well test derivative plot: flow regimes, kh, skin and boundaries
Guide

How to read a well test derivative plot: flow regimes, kh, skin and boundaries

Read a well test derivative plot: unit slope, flat radial flow, half slope, a doubling for a fault, and why several models fit, checked on Utah FORGE data.

A well test derivative plot shows the change in pressure and its derivative against elapsed time, both on logarithmic axes. Each way the fluid flows towards or away from the well leaves its own slope on the derivative: a unit slope while the well itself fills or empties, a flat line once the flow is radial in the reservoir, a half slope for linear flow along a fracture or a channel. Reading those slopes, in order, tells you what a test can measure and what it cannot, before any model is fitted.

What the derivative is, and why it is plotted

The pressure derivative used in well testing is the rate of change of the pressure change with the logarithm of time, Δp′ = dΔp / d ln t. It was popularised by Bourdet and co-workers, who also showed how to compute it on noisy field data: each point uses neighbours at least a window L away in log time, typically 0.1 to 0.3 of a log cycle [1]. A wider window smooths noise but blurs short features, so the window is a choice worth stating.

The reason for the logarithm is radial flow. Once the pressure disturbance spreads radially through the reservoir, the pressure change grows with the logarithm of time at a rate set by the permeability-thickness kh. The derivative on a logarithmic time axis is then flat, at a level of qμ / (4π kh) in consistent units. A flat derivative therefore gives kh directly, and everything before and after it shows what else the well and the reservoir are doing.

For a buildup or an injection falloff, the time axis is not simply the time since shut-in: the earlier rates still act. The derivative is taken on superposition time, which folds the whole rate history into one variable, so that radial flow still plots flat.

The flow regimes and their signatures

Idealised derivative plot with the slopes of the main flow regimes storage: slope 1 radial: flat → kh doubles: one fault closed: slope 1 falls: pressure support log elapsed time log Δp′
An idealised drawdown derivative: wellbore storage, radial flow, a sealing fault, then either a closed volume or pressure support. Shapes only; no data.
  • Wellbore storage: a unit slope. Right after a rate change the well itself supplies or stores the fluid, and the pressure change and its derivative rise together on a 45° line. The storage coefficient C comes from it. Agarwal, Al-Hussainy and Ramey worked out how storage and skin together shape the early curve [2].
  • The hump after storage. Its height grows with the skin. Skin is the extra pressure drop near the well, from damage (positive) or from stimulation and fractures (negative).
  • Radial flow: flat. The level gives kh; the gap between the pressure change and the derivative gives the skin. If the derivative never flattens, kh is not determined by the test, whatever a fitted model says.
  • Linear flow: a half slope. Flow into a vertical fracture early on, or along a channel between two parallel faults late on.
  • Bilinear flow: a quarter slope. A fracture with finite conductivity, where the flow in the fracture and in the rock are both linear.
  • A dip between two flat stretches. The classic sign of dual porosity: fractures drain first, then the rock blocks feed them, as Warren and Root described [3]. A layered reservoir can draw the same dip.
  • A doubling. The derivative steps up to twice its flat level when half of the flow is cut off by one sealing fault. The time of the step gives the distance.
  • A falling derivative. Pressure support: a constant-pressure boundary such as an aquifer or a gas cap, or, around a geothermal injector, hot and more mobile water beyond the cooled zone near the well.
  • A late unit slope in a drawdown. The test has felt the whole volume: a closed reservoir in pseudo-steady state.

From diagnosis to interpretation: why several models fit

The plot tells you which regimes are present; a model turns them into numbers. A good interpretation fits the pressure change and the derivative together and reports each parameter with a range, a P10 to P90, not a single value. The range should come from the scatter of the data, for example from the curvature of the fit and from refitting resampled records.

Interpretation is not unique. A sealing fault, a radial composite reservoir and a dual-porosity reservoir can draw nearly the same curve over the hours or days a test lasts. If two models fit within a few percent of each other, the data do not choose between them; geology, other wells and other tests do. An honest report lists every model that fits about as well, with its own parameters. KAI's Well Test Studio does exactly this: every model within 10 % of the best misfit is shown.

Geothermal injection and falloff tests

In a geothermal injector the water injected is much colder than the reservoir, and cold water is more viscous. A falloff after injection therefore sees two regions: a cooled zone near the well with lower mobility, and hot reservoir beyond it. On the derivative this reads as one flat level and then a lower one, a falling derivative that is easy to mistake for a constant-pressure boundary. A radial composite model, with an inner radius and a mobility ratio, describes it. The water's density, viscosity and compressibility at reservoir temperature and pressure matter for kh, so they should come from a recognised formulation such as IAPWS-IF97 rather than from cold-water values.

Hot wells also bring thermal effects on the gauge and in the water column after each rate change. A downhole gauge reduces them; early minutes of a surface record may say more about the wellbore than about the reservoir.

DFITs: closure and the minimum stress

A diagnostic fracture injection test (DFIT or minifrac) pumps a small volume to open a short fracture, then watches the pressure fall. While the fracture is open and leaks off normally, the pressure falls linearly in the G-function, a time variable from Nolte's work, and G·dP/dG follows a straight line through the origin. Closure is where the curve leaves that line, and the closure pressure is the usual estimate of the minimum horizontal stress, Shmin [4]. A hump above the line points to pressure-dependent leak-off through natural fissures; a curve below it to fracture height recession or tip extension.

The pick matters because Shmin caps the injection pressure of a geothermal doublet and sets how close faults are to slipping. On the public Utah FORGE 16B(78)-32 minifracs, the Well Test Studio's closure agreed with the published report within 5 % in 10 of the 12 cycles where it picked one, and its instantaneous shut-in pressure within 3 % in all 15 cycles it matched [5]. In two cycles it called the leak-off pressure-dependent and picked closure 6–7 % lower than the report's bi-linear method; those misfits are published with the case.

A short checklist before you trust a number

  1. Is there a flat derivative? If not, kh is not determined by the test.
  2. Do you have readings from before the rate change, and do the clocks of the gauge and the rate record agree?
  3. Is the gauge resolution small against the pressure change? Coarse steps turn the derivative into noise.
  4. Were the units right: psi or bar, feet or metres, hours or minutes?
  5. Does more than one model fit? Report them all, with their ranges.
  6. For a DFIT: was closure reached before the record ended, and is the gauge at the test depth?

KAI does not run field tests; it reads them. The Well Test Studio runs in the browser and stores nothing unless you sign in and save a test. Gas tests, horizontal wells, finite-conductivity fractures, layered reservoirs and numerical well-test models are not covered yet. The permeability it measures can be carried straight into the Reservoir Lab, and a DFIT's closure into the fault screen, so the model of the reservoir starts from what the well actually measured.

Sources

  1. Use of pressure derivative in well-test interpretation. Bourdet, D., Ayoub, J.A. and Pirard, Y.M., SPE Formation Evaluation 4(2), 1989
  2. An investigation of wellbore storage and skin effect in unsteady liquid flow: I. Analytical treatment. Agarwal, R.G., Al-Hussainy, R. and Ramey, H.J. Jr., SPE Journal 10(3), 1970
  3. The behavior of naturally fractured reservoirs. Warren, J.E. and Root, P.J., SPE Journal 3(3), 1963
  4. Holistic fracture diagnostics: consistent interpretation of prefrac injection tests using multiple analysis methods. Barree, R.D., Barree, V.L. and Craig, D.P., SPE Production & Operations 24(3), 2009
  5. Utah FORGE 2439: Report on Minifrac Tests for Stress Characterization. U.S. Department of Energy Geothermal Data Repository, submission 1596, CC BY 4.0

Written by KAI Water & Energy. KAI numbers come from the linked case pages and open notebooks; simulated results are marked as simulated. Found an error? Tell us.